• Co-amorphous formulation of dipyridamole with p-hydroxybenzoic acid: Underlying molecular mechanisms, physical stability, dissolution behavior and pharmacokinetic study

    Coamorphization has been proven to be an effective approach to improve bioavailability of poorly soluble active pharmaceutical ingredients (APIs) by virtue of solubilization, and also contributes to overcome limitation of physical stability associated with amorphous drug alone.

    了解更多

    01-26 / 2023

  • Construction of hierarchical porous 3D nanostructures with high specificity as SERS aptasensors for rapid and ultrasensitive detection of MC-LR

    The construction of plasmonic nanostructures is a frontier research area in the field of Surface enhanced Raman scattering (SERS). Three-dimensional (3D) porous materials coupled with aptamers have attracted increasing attention for application in SERS sensing, owing to their great promise towards offering both high specific and ultrasensitive detection capacity. However, most of these SERS sensors are plane-shaped or solution-based, which makes target molecules with a reduced mass transfer, thus leading to a relatively poor capture efficiency. Herein, we demonstrate a capillary-based porous nanostructure coupled with aptamers that can serve as a type of SERS aptasensor for rapid trace detection. The aptasensor was prepared by immobilization of aptamer-modified SERS nanotags on a porous silica monolith which was obtained by an in-situ polymerization in a capillary with a facile fabrication process. The 3D porous silica monolith (3D-PSM) with a hierarchical biporous structure that could enable the rapid permeation of the aqueous phase and provide high specific surface area and active sites, endows the material with high capture efficiency of target molecules. Besides, according to the size of aptamers, stable and uniformed hotspots of 7–8 nm in size were formed, which precisely guaranteed the sensitivity, specificity, and stability of detection. The experimental verification showed that the proposed aptasensor could detect the presence of microcystin-LR at concentrations as low as 0.01 nmol/L, with fast recognition time (10 min), low sample consumption (20 μL), and simple operation. All the results suggest that this new strategy has promising potential in rapid microvolume trace analysis in various fields.

    了解更多

    12-27 / 2022

  • Noninvasive cholangitis and cholangiocarcinoma screening based on serum Raman spectroscopy and support vector machine

    The feasibility of serum Raman spectroscopy for rapid screening of cholangitis and cholangiocarcinoma (CCA) was discussed. Raman spectra were collected from 49 patients with cholangitis, 38 patients with CCA, and 55 healthy volunteers. Normalized mean Raman spectra and spectral attributions reveal disease-specific biomolecular differences. Support vector machine (SVM) was used to establish the two-way (cholangitis vs healthy, CCA vs healthy etc.) and 3-way (cholangitis vs CCA vs healthy) classification model, and leave-one-out cross-validation (LOOCV) was used to verify these models' performance. Based on the support vector machine algorithm, serum Raman spectroscopy could identify cholangitis and CCA. Its diagnostic sensitivity, and specificity were 89.80%, 94.55%, and 89.50%, 98.18%, respectively. This study demonstrates that label-free serum Raman spectroscopy analysis technique combined with SVM diagnostic algorithm has great potential for noninvasive cholangitis and CCA screening.

    了解更多

    10-11 / 2022

  • Catalytic electrodes for the oxygen reduction reaction based on co-doped (B-N, Si-N, S-N) carbon quantum dots and anion exchange ionomer

    B-N-, Si-N, and S-N-co-doped carbon quantum dots (CQD) were prepared by hydrothermal synthesis from
    inexpensive and non-toxic precursors. They were analysed by Raman, FTIR, and XPS spectroscopies and used as
    oxygen reduction reaction (ORR) electrocatalysts. The electrodes were prepared by drop-casting a slurry containing poly(sulfone trimethylammonium) hydroxide (PSU-TMA) to enhance the hydroxide-ion transport near
    the catalytically active centers. Furthermore, polyaniline (PANI), reported to be catalytically active for the ORR,
    was added to some electrodes. A similar trend was observed for the electrode capacitance measured by cyclovoltammetry in the non-Faradaic region and impedance spectroscopy. The ORR kinetics studied by linear sweep
    voltammetry showed the lowest onset and half-wave potentials and the lowest Tafel slopes for the B-N-co-doped
    samples, although the B concentration is low (0.5%). Data with and without PANI are quite similar. The S-N- and
    Si-N co-doped samples are slightly less efficient. The stability test demonstrated a decrease by about 10% of the
    diffusion-limited current after 500 cycles, indicating a microstructural change impacting the mass transport
    conditions, but the onset potential is not modified. Altogether, the good electrocatalytic activity of B-N-co-doped
    CQD with a low boron concentration in presence of PSU-TMA indicated the high potential of these electrodes.
    The inexpensive synthesis of co-doped CQD from non-toxic precursors is an important advantage of these materials vs other carbon-doped electrocatalysts.

    了解更多

    07-16 / 2022

  • Surface-enhanced Raman spectroscopic analysis of centrifugally filtered blood serum samples of hepatitis C patients

    Background: Raman spectroscopy is able to analyze non-invasively, disease related to body fluids. Objectives: For the qualitative and quantitative analysis of HCV serum samples surface-enhanced Raman spectroscopy (SERS) based method is developed. Method: Surface-enhanced Raman spectroscopy (SERS) technique is employed for analysis of filtrate portions of blood serum samples of hepatitis C virus (HCV) infected patients and healthy ones by using 50 kDa centrifugal filter device. The filtrate portions of the serum obtained in this way contain proteins smaller than 50 kDa and removal of bigger size protein which allows to acquire SERS spectral features of smaller proteins more effectively which are probably associated with Hepatitis C infection. Moreover, SERS spectral features of the filtrates of different level of viral load including low, medium and high viral loads are compared with SERS spectral features of the filtrate portions of healthy/control serum samples. SERS spectral data sets of different samples are further analyzed by using multivariate data analysis techniques such as principal component analysis (PCA) and partial least square regression (PLSR). Some SERS spectral features are solely observed in the filtrate portions of the serum samples of hepatitis C and their intensities are increased as the level of viral load increases and might be used for HCV diagnosis. Results: PCA was found helpful for differentiation of SERS spectral data sets of filtrate portions of the serum samples of hepatitis C and healthy persons. The PLSR model helped for the quantification of viral loads in the unknown serum samples with 99% accuracy.

    了解更多

    06-02 / 2022

  • A novel SERS-based rapid and sensitive assay for methidathion detection in various fruits

    This study establishes a sensitive and facile method for trace detection of methidathion (MTDT) by using spherical Ag nanoparticles (Ag NPs) based on surface enhanced Raman scatting (SERS). During detection, MTDT was rapidly alkaline hydrolyzed through SN2 substitution reaction and generated a thiadiazolin derivative with a more stronger Raman activity. After removing hydroxide ions from the solution, a limit of detection (LOD) as low as 0.33 ppb was achieved, which is two orders of magnitude below as compared to the non-hydrolysis group. Base on a self-developed and fast (10 min) pre-treatment method, MTDT was successfully detected in six kinds of fruit. The detection limits were ranged from 5–15 ppb, which were much lower than the maximum residue limit (MRL) required by China, US and the EU. Moreover, multivariate analysis (MVA) method was used for quantitative analysis in apple spiked samples, compared with univariate analysis (UVA), a higher determination coefficient (R2=0.9331) and a better dynamic range (10 ppb–5 ppm) were obtained. The major aim of this work is to provide an operational, fast and sensitive method to specifically detect the MTDT pesticide in real agricultural samples.

    了解更多

    04-25 / 2022

  • Urine surface-enhanced Raman spectroscopy combined with SVM algorithm for rapid diagnosis of liver cirrhosis and hepatocellular carcinoma

    In this paper, we investigated the feasibility of using urine for surface-enhanced Raman spectroscopy (SERS) for the rapid screening of patients with liver cirrhosis and hepatocellular carcinoma (HCC). The SERS spectra were recorded from the urine of 49 liver cirrhosis, 55 HCC, and 50 healthy volunteers using a Raman spectrometer. The normalized mean Raman spectra showed the difference of specific biomolecules associated with the illnesses, and the metabolism of specific nucleic acids and amino acids is abnormal in patients with liver cirrhosis and HCC. Based on the SVM algorithm, the urine SERS method could identify liver cirrhosis (sensitivity 88.9%, specificity 83.3%, and accuracy 85.9%) and HCC (sensitivity 85.5%, specificity 84.0%, and accuracy 84.8%). It has a higher diagnostic sensitivity for HCC than serum Alpha fetoprotein (AFP). This exploratory study showed that the urine SERS spectra combined with the SVM algorithm has indicated great potential in the noninvasive identification of liver cirrhosis and HCC.

    了解更多

    03-15 / 2022

  • Alkali hydrolysis and Lewis acids assisted enhancement based highly sensitive and quantitative detection of malathion in tea using SERS and multivariate analysis

    This study establishes an incredibly simple method for trace detection of malathion (MLT) by using spherical Ag
    nanoparticles (Ag NPs) based on surface enhanced Raman scatting (SERS). MLT was rapidly hydrolyzed through
    β-elimination reaction under alkaline condition, then provided a favorable ionic environment for SERS detection
    by using Lewis acids (LAs), leading to a 305 times maximum additional enhancement, and a limit of detection
    (LOD) as low as 0.1 ppb was achieved. The different alkaline hydrolysis pathways of MLT and other dithiophosphate organophosphorus molecules was clarified, and the conversion of molecular binding states on nanosurface were determined. The method was successfully applied in various tea samples, a LOD as low as 0.05 ppm
    was obtained. Due to the complex variation of characteristic peaks intensity, multivariate analysis method was
    used for quantitative analysis and a high determination coefficient (R2 =0.9573) and good dynamic range of
    0.1–5 ppm were obtained.

    了解更多

    02-16 / 2022

Awesome Image

奥谱天成,成立于2015年,由国际光谱仪器专家刘鸿飞博士创立,总部位于厦门,是一家专注于高端光谱分析仪器研发与制造的国家级专精特新“重点小巨人”企业。

在线留言